Sentence 3.1.8.3.(3)

  1. OS1
  2. OP1
  3. OS1
  4. OP1

Objective

OP1 Fire Protection of the Building

Attribution

(a)[F03-OP1.2]

Intent

Intent 1:

To limit the probability that fire will spread from one fire compartment to another fire compartment through a shaft, which could lead to damage to the building in the other fire compartment.