Sentence 3.3.1.4.(3)

  1. OS1
  2. OP1

Objective

OP1 Fire Protection of the Building

Attribution

Intent

Intent 1:

To exempt fire separations in public corridors from the application of Sentence 3.3.1.4.(2), which would otherwise require the fire separation to have a fire-resistance rating, on the basis that the storey is sprinklered throughout and the corridor does not serve certain occupancies.

This is to limit the probability that a fire will not be suppressed or controlled, which could lead to:

  • the spread of fire into the corridor, or from the corridor to another part of the building, which could lead to damage to the building, and
  • fire emergency response operations being delayed or ineffective, which could lead to the spread of fire to other parts of the building, which could lead to damage to the building.
Top of Page