Sentence 4.2.3.10.(1)

  1. OS2
  2. OP2
  3. OP4

Objective

OP2 Structural Sufficiency of the Building

Attribution

Intent

Intent 1:

To limit the probability that steel components in foundation systems will be exposed to aggressive environmental conditions, which could lead to premature corrosion, which could lead to loss of bearing capacity, which could lead to excessive displacement of the foundation, which could lead to damage to the building.

Intent 2:

To direct Code users to Article 1.2.1.1. of Division A for materials other than described in this Subsection.

Top of Page