Sentence 9.4.4.2.(1)

  1. OS2
  2. OP2
  3. OH1
  4. OH4
  5. OS3

Objective

OS3 Safety in Use

Attribution

[F20-OS3.1]Applies to floors and elements that support floors.

Intent

Intent 1:

To limit the probability that an excessive design capacity of foundations will lead to soil subsidence, which could lead to the cracking of foundations or building superstructures.

This is to limit the probability of:

  • compromised structural integrity, or
  • for environmental separators or elements supporting environmental separators, the displacement or failure of required environmental separation elements, which could lead to the deterioration of building elements, which could lead to compromised structural integrity.

For floors and elements supporting floors, this is to limit the probability of excessive deflection or vibration, which could lead to a loss of balance, tripping or falling, which could lead to harm to persons.

Top of Page