Intent 1:
Where the foundation wall encloses interior spaces,
to limit the probability of the transfer of uplift loads from freezing
soil to the underside of stairs, which could lead to the failure of
the foundation wall at the point of stair attachment, which could
lead to concrete or masonry cracking, which could lead to:
- the ingress of moisture from the ground, or
- compromised thermal performance of components intended
to provide resistance to heat transfer.
This is to limit the probability of:
- an inadequate control of the temperature of interior
spaces, relative humidity, water ingress and accumulation,
- the generation of pollutants from biological growth
or from materials that become unstable on wetting, or
- deterioration, which could lead to compromised integrity
of elements supported or protected by foundations.
This is to limit the probability of:
- negative effects on the air quality of indoor spaces,
- the inadequate thermal comfort of persons, and
- contact with moisture.
This is to limit the probability of harm to persons.