Sentence 9.10.5.1.(4)

  1. OS1
  2. OP1

Objective

OS1 Fire Safety

Attribution

Intent

Intent 1:

To exempt openings leading to ducts from the requirements of Sentence 9.10.5.1.(1), which would otherwise not permit openings in rated ceiling membranes, if certain conditions are met [i.e. the ducts, the amount of openings and their protection conform to the requirements of Appendix B].

This is to limit the probability that openings into rated ceiling membranes will contribute to the spread of fire within the ceiling space, which could lead to the premature failure or collapse of the structure within the ceiling space, which could lead to harm to persons.

Intent 2:

To make the provisions in Appendix B mandatory with respect to:

  • area, size, spacing and support of openings,
  • materials, clearance to ceiling membrane and support for ducts, and
  • thermal protection and fire stop flaps for ducts.