Sentence 9.12.1.2.(1)

  1. OS2
  2. OP2
  3. OH1
  4. OH4
  5. OS3

Objective

OH1 Indoor Conditions

Attribution

[F60-OH1.1,OH1.2,OH1.3]Applies to elements that support or are part of an environmental separator.

Intent

Intent 1:

To limit the probability of saturation of the soil beneath foundations, which could lead to the soil being unable to resist foundation loads, which could lead to excessive settlement, which could lead to structural damage to foundations and superstructures.

For elements supporting environmental separators, this is to limit the probability of:

  • condensation,
  • precipitation ingress,
  • the ingress of moisture from the ground, or
  • compromised thermal performance of components intended to provide resistance to heat transfer.

This is to limit the probability of:

  • an inadequate control of the temperature of interior spaces, drafts, relative humidity, or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • further compromised integrity of foundation walls that act as environmental separators or of elements supported by such walls, which could lead to the deterioration of building elements.

This is to limit the probability of:

  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.

This is to limit the probability of harm to persons.

Top of Page