Sentence 9.15.3.1.(1)

  1. OS2
  2. OP2
  3. OH1
  4. OH4
  5. OS3

Objective

OP2 Structural Sufficiency of the Building

Attribution

[F20,F21-OP2.3]Applies to elements that support or are part of an environmental separator.

Intent

Intent 1:

To limit the probability of insufficient bearing area for foundations, which could lead to compressive failure and settlement of the underlying soil, which could lead to structural damage to the foundation and the building, which could lead to an inability to support vertical building loads or lateral earth loads.

This is to limit the probability of compromised structural integrity, which could lead to:

  • structural failure,
  • where elements support or are part of an environmental separator, the displacement or failure of required environmental separation elements, which could lead to the deterioration of building elements, or
  • an inability to resist expected loads, which could lead to
    • the excessive deformation or deflection of walls, or
    • the excessive deflection or vibration of floors.

This is to limit the probability of:

  • the space being unsuitable for its intended use, or
  • damage to the building.
Top of Page