Intent 1:
To limit the probability of inadequate protection,
which could lead to beam ends being exposed to water from rain or
melting snow, which could lead to rotting or corrosion of the ends
of beams.
Where elements support or are part of
an environmental separator, this is to limit the probability of:
- condensation,
- rainwater ingress,
- the ingress of moisture from the ground, or
- compromised thermal performance of components intended
to provide resistance to heat transfer.
This is to limit the probability of:
- an inadequate control of temperatures of interior spaces,
relative humidity, or water accumulation,
- the generation of pollutants from biological growth
or from materials that become unstable on wetting, or
- compromised integrity of elements supported by the beam,
which could lead to the deterioration of building elements.
This is to limit the probability of:
- negative effects on the air quality of indoor spaces,
- the inadequate thermal comfort of persons, and
- contact with moisture.
This is to limit the probability of harm to persons.