Sentence 9.15.5.3.(3)

  1. OS2
  2. OP2
  3. OH1
  4. OH4
  5. OS3

Objective

OS2 Structural Safety

Attribution

[F20-OS2.3]Applies to elements that support or are part of an environmental separator.

Intent

Intent 1:

To limit the probability of inadequate strength, which could lead to an inability to resist concentrated loads from beams, which could lead to the compression failure of hollow concrete blocks and the transfer of gravity loads to thin foundation walls, which could lead to foundation walls cracking.

This is to limit the probability of compromised structural integrity, which could lead to:

  • structural failure, or
  • where elements support or are part of an environmental separator, the displacement or failure of required environmental separation elements, which could lead to the deterioration of building elements.

This is to limit the probability of harm to persons.