Sentence 9.20.6.2.(1)

  1. OH1
  2. OS2
  3. OP2
  4. OS1
  5. OH4
  6. OS3

Objective

OP2 Structural Sufficiency of the Building

Attribution

[F20,F22-OP2.3]Applies to elements that support or are part of an environmental separator or are exposed to moisture.

Intent

Intent 1:

To limit the probability of:

  • inadequate width of masonry units in loadbearing contact with each other, which could lead to an inability to resist expected gravity or lateral loads,
  • insufficient bond strength to resist tensile stresses in non-loadbearing masonry cavity walls, or
  • inadequate bonding of ties with mortar, which could lead to inadequate pullout and pushout resistance.

This is to limit the probability of:

  • compromised structural integrity of masonry construction,
  • where masonry construction is part of an environmental separator, the displacement or failure of required environmental separation elements, which could lead to deterioration,
  • in assemblies exposed to moisture or the exterior, damage and deterioration, or
  • an inability to resist expected loads, which could lead to:
    • the excessive movement or deformation of walls, or
    • the excessive deflection or vibration of floors.

This is to limit the probability of:

  • the space being unsuitable for its intended use,
  • compromised operation of windows or doors, or
  • damage to the building.
Top of Page