Objective

OS1 Fire Safety

Attribution

Intent

Intent 1:

To limit the probability of rain, or melting snow or ice, entering the cavities between wythes of masonry.

Where masonry construction is required to provide fire resistance, this is to limit the probability of precipitation or meltwater ingress, which could lead to deterioration due to freeze-thaw stresses, which could lead to compromised fire resistance of the assembly, which could lead to harm to persons.