Sentence 9.20.8.2.(3)

  1. OH1
  2. OS2
  3. OP2
  4. OS1
  5. OH4
  6. OS3

Objective

OH1 Indoor Conditions

Attribution

[F20-OH1.1,OH1.2,OH1.3]Applies to elements that support or are part of an environmental separator.

Intent

Intent 1:

To limit the probability of an inadequate distribution of roof or floor loads between wythes, which could lead to over-stressing of cavity walls.

Where masonry units support or are part of an environmental separator, this is to limit the probability of:

  • excessive moisture transfer through masonry units, or
  • deformation or cracking, which could lead to the displacement or failure of required environmental separation elements.

This is to limit the probability of:

  • condensation,
  • precipitation ingress,
  • moisture ingress,
  • excessive heat transfer,
  • pollutant ingress, or
  • compromised thermal performance of components intended to resist heat transfer.

This is to limit the probability of:

  • an inadequate control of temperatures in interior spaces, drafts, relative humidity or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to further compromised integrity of environmental separators.

This is to limit the probability of:

  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.

This is to limit the probability of harm to persons.