Sentence 9.20.8.4.(5)

  1. OH1
  2. OS2
  3. OP2
  4. OS1
  5. OH4
  6. OS3

Objective

OS1 Fire Safety

Attribution

[F20,F22-OS1.2]Applies to assemblies required to provide fire resistance.

Intent

Intent 1:

To limit the probability that pilasters will be unable to resist the loads imposed by beams or columns, which could lead to structural failure of unit-masonry pilasters and cracking of masonry walls.

Where masonry construction is required to provide fire resistance, this is to limit the probability of compromised fire resistance of the assembly, which could lead to harm to persons.

Top of Page