Intent 1:
To limit the probability of:
- flexural failure of the masonry spanning between intermediate
tie locations,
- tie pullout or pushthrough (i.e. embedment failure),
- ties buckling, or
- tie material failure.
This is to limit the probability of cracking or buckling
of cavity wall constructions.
Where masonry units support or are part of an environmental
separator, this is to limit the probability of:
- excessive moisture transfer through masonry units, or
- deformation or cracking, which could lead to the displacement
or failure of required environmental separation elements.
This is to limit the probability of:
- condensation,
- precipitation ingress,
- moisture ingress,
- excessive heat transfer,
- pollutant ingress, or
- compromised thermal performance of components intended
to resist heat transfer.
This is to limit the probability of:
- an inadequate control of temperatures in interior spaces,
drafts, relative humidity or water accumulation,
- the generation of pollutants from biological growth
or from materials that become unstable on wetting, or
- deterioration, which could lead to further compromised
integrity of environmental separators.
This is to limit the probability of:
- negative effects on the air quality of indoor spaces,
- the inadequate thermal comfort of persons, and
- contact with moisture.
This is to limit the probability of harm to persons.