Sentence 9.20.11.2.(2)

  1. OH1
  2. OS2
  3. OP2
  4. OS1
  5. OH4
  6. OS3

Objective

OS2 Structural Safety

Attribution

[F20-OS2.3]Applies to elements that support or are part of an environmental separator.

Intent

Intent 1:

To limit the probability of:

  • inadequate interlocking of supporting walls with supported walls, and
  • concentrations of stress at points of connection.

This is to limit the probability of failure of connections between intersecting walls under lateral loads, which could lead to an inability to transfer lateral loads from masonry walls to intersecting walls intended to provide lateral support, which could lead to inadequate lateral stiffness, which could lead to an inability to resist lateral loads or inadequate distribution of gravity loads, which could lead to cracking or buckling.

This is to limit the probability of compromised structural integrity, which could lead to:

  • structural failure of masonry construction, or
  • where masonry construction is part of an environmental separator, the excessive deformation, displacement or failure of required environmental separation elements, which could lead to deterioration, which could lead to further compromised structural integrity.

This is to limit the probability of harm to persons.