Sentence 9.20.11.3.(1)

  1. OH1
  2. OS2
  3. OP2
  4. OS1
  5. OH4
  6. OS3

Objective

OH4 Vibration and Deflection Limitation

Attribution

[F20,F22,F80-OH4]Applies to floors and elements that support floors.

Intent

Intent 1:

To limit the probability of:

  • failure of steel-rod ties, or
  • inadequate lateral load distribution, which could lead to failure of the connection between intersecting walls.

This is to limit the probability of an inability to transfer lateral loads from framed walls to intersecting walls, which could lead to inadequate lateral stiffness, which could lead to an inability to resist lateral loads or inadequate distribution of gravity loads, which could lead to cracking or buckling.

This is to limit the probability of:

  • compromised structural integrity of masonry construction,
  • where masonry construction is part of an environmental separator, the displacement or failure of required environmental separation elements, which could lead to deterioration.

For floors and elements supporting floors, this is to limit the probability of excessive movement, deflection or vibration, which could lead to negative effects on the psychological well-being of persons.

Top of Page