Intent 1:
To limit the probability of the failure of connectors,
which could lead to inadequate flexural strength of masonry.
Where exterior masonry walls support an environmental separator
or act as one, this is to limit the probability of deformation or
cracking, which could lead to the excessive deformation, displacement
or failure of required environmental separation elements.
This is to limit the probability of:
- condensation,
- precipitation ingress,
- moisture ingress,
- excessive heat transfer,
- pollutant ingress, or
- compromised thermal performance of components intended
to resist heat transfer.
This is to limit the probability of:
- an inadequate control of temperatures in interior spaces,
drafts, relative humidity or water accumulation,
- the generation of pollutants from biological growth
or from materials that become unstable on wetting, or
- deterioration, which could lead to further compromised
integrity of environmental separators.
This is to limit the probability of:
- negative effects on the air quality of indoor spaces,
- the inadequate thermal comfort of persons, and
- contact with moisture.
This is to limit the probability of harm to persons.