Intent 1:
To limit the probability of discontinuity of top
plates, which could lead to an inability to resist expected gravity
and lateral loads, which could lead to:
- the inadequate transfer of vertical loads to and from
studs, which could lead to the excessive deflection or failure of
wall plates, or
- inadequate diaphragm action of plates, which could lead
to the excessive deflection of walls.
For floors and constructions supporting
floors, this is to limit the probability of:
- compromised structural integrity, or
- for exterior floors or environmental separators supporting
a floor, the excessive deformation, displacement or failure of required
environmental separation elements, which could lead to deterioration,
which could lead to further compromised structural integrity.
This is to limit the probability of excessive movement,
vibration or deflection of floors, which could lead to negative effects
on the psychological well-being of persons.