Sentence 9.23.14.2.(1)

  1. OS2
  2. OP2
  3. OH1
  4. OS1

Objective

OP2 Structural Sufficiency of the Building

Attribution

[F20,F22-OP2.3]Applies to elements that support or are part of an environmental separator.

Intent

Intent 1:

To limit the probability of inadequate strength or stiffness, which could lead to an inability to resist expected gravity or wind loads transferred to framing around openings, which could lead to the excessive deflection or failure of roofs.

This is to limit the probability of compromised structural integrity, which could lead to:

  • the structural collapse of wood-frame construction,
  • where roof and ceiling framing members support required elements of environmental separators, the excessive deformation, displacement or failure of these elements, which could lead to deterioration, which could lead to further compromised structural integrity of roofs or environmental separators, or
  • where roof and ceiling framing members support assemblies exposed to the exterior, excessive water ingress, which could lead to deterioration.

This is to limit the probability of damage to the building.