Sentence 9.25.2.4.(6)

  1. OH1
  2. OS2

Objective

OS2 Structural Safety

Attribution

Intent

Intent 1:

To limit the probability of:

  • [Clause 9.25.2.4.(6)(a)] inadequate attic or roof space ventilation, and
  • [Clause 9.25.2.4.(6)(b)] inadequate thermal resistance.

This is to limit the probability of:

  • condensation, which could lead to the accumulation of moisture,
  • the formation of ice dams, which could lead to the ingress of melted water,
  • compromised thermal performance of components intended to provide resistance to heat transfer, or
  • excessively low temperatures of interior surfaces or within assemblies.

This is to limit the probability of deterioration, which could lead to compromised structural integrity of assemblies acting as environmental separators, which could lead to harm to persons.

Top of Page