Sentence 9.27.5.1.(3)

  1. OH1
  2. OS2

Objective

OS2 Structural Safety

Attribution

Intent

Intent 1:

To limit the probability of fastening cladding to an inappropriate substrate, which could lead to an inadequate resistance to expected gravity loads and lateral wind loads.

This is to limit the probability of:

  • the displacement of cladding, trim and flashing, the opening of joints or the failure of caulking, which could lead to precipitation or meltwater ingress, which could lead to deterioration, which could lead to the structural failure of exterior walls or elements protected by exterior walls, or
  • falling cladding components.

This is to limit the probability of harm to persons.

Intent 2:

To supersede the fastening requirement stated in Sentence 9.27.5.1.(1) and allow some cladding materials to be fastened to sheathing where the sheathing offers sufficient strength to support the specific cladding material.

Top of Page