Intent 1:
To limit the probability of checking or splitting
due to cyclical changes in moisture content, and attendant swelling
and shrinkage, which could lead to the displacement of cladding, trim
and flashing, opening of joints or failure of caulking, which could
lead to:
- precipitation or meltwater ingress, or
- compromised thermal performance of components intended
to provide resistance to heat transfer.
This is to limit the probability of:
- an inadequate control of temperatures of interior spaces
or relative humidity,
- the generation of pollutants from biological growth
or from materials that become unstable on wetting,
- deterioration, which could lead to compromised integrity
of exterior walls or elements protected by exterior walls, or
- water accumulation in interior spaces.
This is to limit the probability of:
- negative effects on the air quality of indoor spaces,
- the inadequate thermal comfort of persons, and
- contact with moisture.
This is to limit the probability of harm to persons.