Sentence 9.27.9.2.(1)

  1. OH1
  2. OS2
  3. OP2

Objective

OP2 Structural Sufficiency of the Building

Attribution

[F20-OP2.1,OP2.3,OP2.4][F22-OP2.3,OP2.4,OP2.5]Applies where panel-type cladding is installed to provide the required bracing.

Intent

Intent 1:

To limit the probability that hardboard cladding will not be strong enough or rigid enough.

Where panel-type cladding is installed as bracing to satisfy Subclause 9.23.13.1.(2)(a)(i) and Clause 9.23.13.6.(1)(a), this is to limit the probability of an inadequate resistance to lateral loads, which could lead to racking of exterior walls.

This is to limit the probability of:

  • the deformation of the building, or
  • the excessive deformation, displacement or failure of required environmental separation elements, which could lead to deterioration, which could lead to compromised structural integrity of exterior walls or of elements supported or protected by exterior walls, or
  • falling cladding components.

This is to limit the probability of:

  • the space being unsuitable for its intended use,
  • compromised operation of windows and doors, or
  • damage to the building.
Top of Page