Sentence 9.29.10.4.(1)

  1. OH1
  2. OS2
  3. OS1
  4. OP2

Objective

OS1 Fire Safety

Attribution

[F20-OS1.2]Applies where the substrate is required to act as fire protection for foamed plastics or to contribute to the required fire resistance of assemblies.

Intent

Intent 1:

To limit the probability that the tile substrate will have an inadequate resistance to water.

This is to limit the probability of the deterioration of the substrate, which could lead to:

  • where the substrate is required to protect foamed plastics, a loss of fire protection, or
  • where the substrate is required to contribute to the required fire resistance of assemblies, a loss of fire resistance.

This is to limit the probability of the growth and spread of fire, which could lead to harm to persons.

Top of Page