Sentence 4.1.5.1.(1)

  1. OS2
  2. OP2
  3. OH4

Objective

OP2 Structural Sufficiency of the Building

Attribution

Intent

Intent 1:

To limit the probability that the live load due to use and occupancy, which is used for the design of structural elements, will not take into account the most critical of the uniformly distributed specified live load, the live load resulting from the intended use or the concentrated specified live load, which could lead to:

  • the excessive deformation of, or excessive stress in, structural elements, which could lead to damage to the building, or
  • the excessive deflection or excessive vibration of structural elements, which could impede the intended use and occupancy of the building.

Intent 2:

To direct Code users to Sentence 4.1.5.3.(1) for specified uniformly distributed live load due to use and occupancy, and to Sentence 4.1.5.9.(1) for specified concentrated live load due to use and occupancy.

Intent 3:

To direct Code users to Sentence 4.1.5.1.(2) for buildings in the Low Importance Category according to Table 4.1.2.1.

Top of Page