Sentence 5.2.2.2.(2)

  1. OS2
  2. OH1
  3. OH4

Objective

OH4 Vibration and Deflection Limitation

Attribution

Intent

Intent 1:

To limit the probability of using inappropriate wind load assumptions, which could lead to the deflection, movement and deterioration of required environmental separation elements subject to wind load, which could lead to the failure of such elements, which could lead to the inadequate control of:

  • precipitation ingress due to air pressure differences,
  • condensation, or
  • the ingress of airborne moisture from the ground.

This is to limit the probability of vibration and deflection, which could lead to negative effects on the psychological well-being of persons.

Intent 2:

To expand the application of Article 4.1.7.3. to wind loads on elements identified in Sentences 5.1.4.1.(4) and 5.2.2.2.(1), with respect to the direct implications of non-compliance with the objectives of Structural Safety and Structural Sufficiency of the Building.

Top of Page