Sentence 9.15.4.5.(2)

  1. OS2
  2. OP2
  3. OH1
  4. OH4
  5. OS3

Objective

OS3 Safety in Use

Attribution

[F20,F22-OS3.1]Applies to floors and elements that support floors.

Intent

Intent 1:

To limit the probability of insufficient vertical reinforcement or that the vertical reinforcement will not be adequately encased and bonded to the concrete, or will be unable to support lateral earth loads, which could lead to concrete cracking or the displacement of foundation walls.

This is to limit the probability of:

  • compromised structural integrity, or
  • where elements support or are part of an environmental separator, the displacement or failure of required environmental separation elements, which could lead to the deterioration of building elements.

For floors and elements supporting floors, this is to limit the probability of excessive deflection, which could lead to rough or uneven walking surfaces, which could lead to persons tripping or falling, which could lead to harm to persons.

Top of Page