Sentence 9.19.1.2.(5)

  1. OS2
  2. OH1
  3. OH2

Objective

OH1 Indoor Conditions

Attribution

[F42-OH1.1]Applies to resistance to the entry of insects.

Intent

Intent 1:

To limit the probability that the performance of vents will fall significantly below expectations with respect to:

  • material integrity and durability, including corrosion resistance, which could lead to the premature failure of vents,
  • flashing provided by flanges,
  • wind and rain resistance,
  • protection against the ingress of insects or vermin, and
  • net ventilating area.

This is to limit the probability of:

  • precipitation ingress,
  • an infestation of insects or vermin, and
  • insufficient venting, which could lead to:
    • condensation, or
    • the formation of ice dams, which could lead to the ingress of water.

This is to limit the probability of:

  • compromised thermal performance of components intended to provide resistance to heat transfer, which could lead to an inadequate control of the temperature of interior spaces,
  • the generation of pollutants from insects or biological growth or from materials that become unstable on wetting,
  • deterioration, which could lead to compromised integrity of ceilings acting as environmental separators, or
  • water accumulation in interior spaces.

This is to limit the probability of:

  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.

This is to limit the probability of harm to persons.