Intent 1:
To limit the probability that such concrete blocks
will be of inadequate mass or absorb excessive amounts of water, which
could lead to inadequate resistance to freeze-thaw stresses.
This is to limit the probability of compromised structural
integrity, which could lead to:
- structural failure,
- where elements support or are part of an environmental
separator, the displacement or failure of required environmental separation
elements, which could lead to the deterioration of building elements,
or
- an inability to resist expected loads, which could lead
to:
- the excessive deformation or deflection of walls, or
- the excessive deflection or vibration of floors.
This is to limit the probability of:
- the space being unsuitable for its intended use, or
- damage to the building.