Sentence 9.20.17.2.(1)

  1. OS2
  2. OP2
  3. OH1
  4. OH4
  5. OS3

Objective

OP2 Structural Sufficiency of the Building

Attribution

[F20,F22-OP2.3]Applies to elements that support or are part of an environmental separator.

Intent

Intent 1:

To limit the probability that the placement or amount and spacing of horizontal reinforcement will not be adequate:

  • to ensure the reinforcement is encased and bonded to the concrete, or
  • to limit cracking due to temperature changes and shrinkage.

This is to limit the probability of compromised structural integrity, which could lead to:

  • structural failure,
  • where elements support or are part of an environmental separator, the displacement or failure of required environmental separation elements, which could lead to the deterioration of building elements, or
  • an inability to resist expected loads, which could lead to:
    • the excessive deformation or deflection of walls, or
    • the excessive deflection or vibration of floors.

This is to limit the probability of:

  • the space being unsuitable for its intended use, or
  • damage to the building.
Top of Page