To limit the probability that the flow of outdoor air through the furnace, which is needed to balance the actual normal operating exhaust capacity of the principal ventilation fan, will exceed the amount that can be tempered by the available return airflow to a temperature that is safe for the furnace heat exchanger.
This is to limit the probability of:
This is to limit the probability of cracking or premature failure of heat exchangers, which could lead to:
This is to limit the probability of:
This is to limit the probability of harm to persons.
[Clause 9.32.3.4.(2)(b)] Where the normal operating exhaust capacity of the principal ventilation fan exceeds the maximum permitted outdoor airflow, and the system does not incorporate means for tempering outdoor air, to direct Code users to Clause 9.32.3.1.(1)(a) or Article 9.32.3.5.