[Clause 9.32.3.5.(3)(a)] To limit the probability of the operation of principal ventilation fans when outdoor air supply fans are not operating, which could lead to excessive depressurization, which could lead to:
This is to limit the probability of the inadequate control of:
This is to limit the probability of negative effects on the air quality of indoor spaces, which could lead to harm to persons.
[Clause 9.32.3.5.(3)(b)] To limit the probability of the operation of supply fans when principal ventilation fans are not operating, which could lead to excessive pressurization, which could lead to condensation within assemblies, which could lead to the generation of pollutants from biological growth or from materials that become unstable on wetting.
This is to limit the probability of negative effects on the air quality of indoor spaces, which could lead to harm to persons.