Sentence 4.1.7.11.(1)

  1. OS2
  2. OP2

Objective

OP2 Structural Sufficiency of the Building

Attribution

Intent

Intent 1:

To limit the probability that the effects of wind loads on the exterior ornamentations, equipment and appendages on the structure will not be considered, which could lead to:

  • the excessive deformation of, or excessive stress in, structural elements, which could lead to damage to the building, or
  • the excessive deflection or excessive vibration of structural elements, which could impede the intended use and occupancy of the building.

Intent 2:

To limit the probability that the increased wind exposed area due to ice accretion will not be considered or that it will be determined by an inappropriate method, which could lead to:

  • the excessive deformation of, or excessive stress in, structural elements, which could lead to damage to the building, or
  • the excessive deflection or excessive vibration of structural elements, which could impede the intended use and occupancy of the building.
Top of Page