Sentence 9.29.9.3.(2)

  1. OS2
  2. OP2
  3. OS1
  4. OS3
  5. OH4
  6. OH1
  7. +

Objective

OH4 Vibration and Deflection Limitation

Attribution

[F20,F22-OH4]Applies to walls that support floors.

Intent

Intent 1:

To limit the probability of inadequate fastening for OSB and waferboard interior finishes in required braced wall panels, which could lead to an inability to resist expected lateral loads, which could lead to excessive racking.

For floors and constructions supporting floors, this is to limit the probability of:

  • compromised structural integrity, or
  • for exterior walls supporting a floor, the excessive deformation, displacement or failure of required environmental separation elements, which could lead to deterioration, which could lead to further compromised structural integrity.

This is to limit the probability of excessive movement, vibration or deflection of floors, which could lead to negative effects on the psychological well-being of persons.