Sentence 9.36.2.11.(2)

  1. OE1
  2. +

Objective

OE1 Resources

Attribution

Intent

Intent 1:

To limit the probability that areas of fenestration will be traded-off against opaque areas, which could lead to:

  • not accounting for solar heat gain, and
  • trade-off calculations not being calculated within the limits of conductive heat loss.

This is to limit the probability of excessive thermal transfer through the building envelope, which could lead to excessive use of energy for heating and cooling, which could lead to an unacceptable effect on the environment.