Sentence 9.23.3.1.(2)

  1. OS2
  2. OP2
  3. OS1
  4. OH1
  5. OH4
  6. OS3

Objective

OH1 Indoor Conditions

Attribution

[F20,F22-OH1.1,OH1.2,OH1.3]Applies to elements that support or are part of an environmental separator.

Intent

Intent 1:

To limit the probability that nails of insufficient diameter will be used, which could lead to inadequate withdrawal resistance, pull-through resistance or shear strength, which could lead to an inability to resist expected vertical or lateral loads, which could lead to fastened elements detaching from supporting members.

Where wood-frame construction supports or is part of an environmental separator, this is to limit the probability of the displacement or failure of required environmental separation elements, which could lead to:

  • condensation,
  • precipitation ingress,
  • excessive heat transfer,
  • pollutant ingress, or
  • compromised thermal performance of components intended to resist heat transfer.

This is to limit the probability of:

  • inadequate control of temperatures of interior spaces, drafts, relative humidity or water accumulation,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting, or
  • deterioration, which could lead to further compromised integrity of environmental separators.

This is to limit the probability of:

  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.

This is to limit the probability of harm to persons.