Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.27.3.8.(2)
OS2OH1OS2OH1
ObjectiveOS2 Structural Safety
Attribution
(b)(i),(c)(ii) [F61,F62-OS2.3] Applies to cladding installed outboard of a drained and vented air space.
Application
Application 1: 
Flashing for horizontal joints in cladding, and where cladding substrates change and the substrates differ sufficiently for stresses to be concentrated along the line of horizontal change, in cladding assemblies to which Subsection 9.27.3. applies [see Article 9.27.1.1. for application of Subsection 9.27.3., and where the cladding above and below the joint is outboard of a drained and vented air space.
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate dissipation of precipitation or meltwater to the exterior, which could lead to the excessive accumulation of moisture.
This is to limit the probability of deterioration, which could lead to compromised structural integrity of exterior walls or elements protected by exterior walls, which could lead to harm to persons.
Intent 2: 
To limit the application of Sentence 9.27.3.8.(1), where the wall assembly is constructed such that:
  • precipitation or meltwater ingress at horizontal joints will be minimized, or
  • moisture that bypasses the cladding will be dissipated.