Sentence 9.3.1.9.(2)

  1. OH1
  2. OS2
  3. OP2
  4. OS1
  5. OS3
  6. OH4

Objective

OS1 Fire Safety

Attribution

[F20-OS1.1]Applies to concrete that supports or is used in chimneys or fireplaces.

Intent

Intent 1:

To limit the probability of:

  • interruption of the hydration process,
  • freezing and expansion of internal water, and
  • over-watering due to the melting of ice.

This is to limit the probability of the failure of internal bonds in the concrete, which could lead to reduced compressive strength, which could lead to an inadequate resistance to:

  • expected environmental or structural loads, or
  • air and moisture transfer.

Where concrete supports or is used in chimneys or fireplaces, this is to limit the probability of the compromised integrity of the chimney or fireplace, which could lead to the ignition of combustible building components.

This is to limit the probability of harm to persons.

Top of Page