Intent 1:
To limit the probability of: 
- excessively rapid corrosion, which could lead to the
excessive deflection or structural failure of lintels, or
 - the accumulation of corrosion by-products between lintels
and masonry, which could lead to compressive stresses. 
 
Where masonry units support or are part of an environmental
separator, this is to limit the probability of: 
- excessive moisture transfer through masonry units, or
 - deformation or cracking, which could lead to the displacement
or failure of required environmental separation elements.
 
This is to limit the probability of: 
- condensation, 
 - precipitation ingress,
 - moisture ingress,
 - excessive heat transfer,
 - pollutant ingress, or 
 - compromised thermal performance of components intended
to resist heat transfer.
 
This is to limit the probability of: 
- an inadequate control of temperatures in interior spaces,
drafts, relative humidity or water accumulation,
 - the generation of pollutants from biological growth
or from materials that become unstable on wetting, or
 - deterioration, which could lead to further compromised
integrity of environmental separators.
 
This is to limit the probability of:
- negative effects on the air quality of indoor spaces,
 - the inadequate thermal comfort of persons, and 
 - contact with moisture. 
 
This is to limit the probability of harm to persons.