Sentence 9.28.5.3.(2)

  1. OH1
  2. OS2
  3. OS1
  4. OS3
  5. OP1

Objective

OP1 Fire Protection of the Building

Attribution

[F20,F80-OP1.1]Applies where stucco is applied to masonry chimneys.

Intent

Intent 1:

To limit the probability of compromised cohesion and inadequate adhesion of stucco to the substrate, which could lead to inadequate strength to resist gravity, lateral, impact or abrasion loads, or freeze-thaw stresses, which could lead to the cracking of stucco.

Where stucco is applied to masonry chimneys, this is to limit the probability of precipitation or meltwater ingress, which could lead to the premature failure of chimney liners, which could lead to the escape of heat or flames, which could lead to the ignition of combustible building components, which could lead to damage to the building. [See intent for Sentence 9.21.4.6.(1).]