Sentence 9.28.6.3.(1)

  1. OH1
  2. OS2
  3. OS1
  4. OS3
  5. OP1

Objective

OP1 Fire Protection of the Building

Attribution

[F20,F80-OP1.1]Applies where stucco is applied to masonry chimneys.

Intent

Intent 1:

To limit the probability of:

  • drying before hydration is complete (or inadequate curing),
  • the inadequate embedment of lath, which could lead to the corrosion of lath, or
  • the excessive shrinkage of stucco under gravity or lateral loads, which could lead to cracking.

This is to limit the probability of an inadequate bond between lath and stucco, and the inadequate strength of stucco, which could lead to:

  • excessive moisture transfer by capillary action, or
  • inadequate strength to resist gravity, lateral, impact or abrasion loads, or freeze-thaw stresses.

Where stucco is applied to masonry chimneys, this is to limit the probability of precipitation or meltwater ingress, which could lead to the premature failure of chimney liners, which could lead to the escape of heat or flames, which could lead to the ignition of combustible building components, which could lead to damage to the building. [See intent for Sentence 9.21.4.6.(1).]