Sentence 4.1.6.2.(8)

  1. OS2
  2. OP2
  3. OS2
  4. OP2

Objective

OS2 Structural Safety

Attribution

[F20-OS2.1]Applies to portion of Code text: “The accumulation factor, Ca, shall be 1.0, …”

Intent

Intent 1:

To limit the probability that the accumulation factor will not take into account the roof configuration affecting the maximum expected accumulation of snow on roof areas, which could lead to structural failure, which could lead to harm to persons.

Intent 2:

To limit the probability that the value of the accumulation factor used for roof areas will be less than 1.0 where not warranted, which could lead to structural failure, which could lead to harm to persons.

Top of Page