Sentence 4.1.6.2.(8)

  1. OS2
  2. OP2
  3. OS2
  4. OP2

Objective

OP2 Structural Sufficiency of the Building

Attribution

[F20-OP2.1][F22-OP2.4]Applies to portion of Code text: “The accumulation factor, Ca, shall be 1.0, …”

Intent

Intent 1:

To limit the probability that the accumulation factor will not take into account the roof configuration affecting the maximum expected accumulation of snow on roof areas, which could lead to the excessive deformation of, or excessive stress in, structural elements, which could lead to damage to the building.

Intent 2:

To limit the probability that the value of the accumulation factor used for roof areas will be less than 1.0 where not warranted, which could lead to the excessive deformation of, or excessive stress in, structural elements, which could lead to damage to the building.