Sentence 9.3.1.7.(1)

  1. OS2
  2. OP2
  3. OH1
  4. OH4
  5. OS3
  6. OS1
  7. OS2
  8. OP2
  9. OH1
  10. OS3
  11. OS2
  12. OS3
  13. OP2

Objective

OP2 Structural Sufficiency of the Building

Attribution

(a) [F20,F55,F61-OP2.3]Applies to elements that support or are part of an environmental separator.

Intent

Intent 1:

To limit the probability of:

  • an inappropriate cement/aggregate ratio, or
  • excessive water in concrete.

This is to limit the probability of:

  • aggregate segregation,
  • reduced compressive strength,
  • increased shrinkage and cracking, or
  • low resistance to air and moisture transfer for foundation walls and basement floors, de-icing salts, water absorption or freeze-thaw stresses.

This is to limit the probability of compromised structural integrity, which could lead to:

  • structural failure,
  • where concrete supports or is used in an environmental separator, the displacement or failure of required environmental separation elements, which could lead to the deterioration of building elements, which could lead to further compromised structural integrity, or
  • where concrete supports walls or floors, an inability to resist expected loads, which could lead to
    • the excessive deformation or deflection of walls, or
    • the excessive deflection or vibration of floors.

This is to limit the probability of:

  • the space being unsuitable for its intended use,
  • compromised operation of windows and doors, and
  • damage to the building.
Top of Page