Intent 1:
To limit the probability of:
- an inappropriate cement/aggregate ratio, or
- excessive water in concrete.
This is to limit the probability of:
- aggregate segregation,
- reduced compressive strength,
- increased shrinkage and cracking, or
- low resistance to air and moisture transfer.
This is to limit the probability of compromised structural
integrity, which could lead to:
- structural failure,
- where concrete is used in an environmental separator,
the displacement or failure of required environmental separation elements,
which could lead to the deterioration of building elements, which
could lead to further compromised structural integrity, or
- excessive deflection or cracking of floors.
This is to limit the probability of:
- the space being unsuitable for its intended use, and
- damage to the building.