Sentence 9.27.5.1.(1)

  1. OS2
  2. OP2
  3. OH1
  4. OH4
  5. OS3

Objective

OH1 Indoor Conditions

Attribution

[F20,F22-OH1.1,OH1.2,OH1.3]Applies where panel-type cladding is installed to provide the required bracing.

Intent

Intent 1:

To limit the probability of fastening cladding to an inappropriate substrate.

This is to limit the probability of:

  • an inadequate resistance to expected gravity loads and lateral wind loads, or
  • where panel-type siding is installed as bracing to satisfy Subclause 9.23.13.1.(2)(a)(i) and Clause 9.23.13.6.(1)(a), an inadequate resistance to expected lateral loads, which could lead to racking of exterior walls.

This is to limit the probability of:

  • the displacement of cladding, trim and flashing, the opening of joints or the failure of caulking, or
  • where panel-type siding is installed as bracing to satisfy Subclause 9.23.13.1.(2)(a)(i) and Clause 9.23.13.6.(1)(a), the displacement or failure of other required environmental separation elements.

This is to limit the probability of:

  • precipitation or meltwater ingress, or
  • compromised thermal performance of components intended to provide resistance to heat transfer.

This is to limit the probability of:

  • an inadequate control of the temperature of interior spaces or relative humidity,
  • the generation of pollutants from biological growth or from materials that become unstable on wetting,
  • deterioration, which could lead to compromised integrity of exterior walls or elements protected by exterior walls, or
  • water accumulation in interior spaces.

This is to limit the probability of:

  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.

This is to limit the probability of harm to persons.