Sentence 9.27.5.1.(1)

  1. OS2
  2. OP2
  3. OH1
  4. OH4
  5. OS3

Objective

OS3 Safety in Use

Attribution

[F20,F22-OS3.1]Applies where panel-type cladding is installed to provide the required bracing of walls that support floors.
[F20,F22-OS3.7]Applies where panel-type cladding is installed to provide required bracing of walls that contain doors or windows required for emergency egress.

Intent

Intent 1:

To limit the probability of fastening cladding to an inappropriate substrate.

Where panel-type siding is installed as bracing to satisfy Subclause 9.23.13.1.(2)(a)(i) and Clause 9.23.13.6.(1)(a), this is to limit the probability of an inadequate resistance to lateral loads, which could lead to racking of exterior walls, which could lead to:

  • compromised structural integrity, or
  • the excessive deformation, displacement or failure of required environmental separation elements, which could lead to deterioration, which could lead to further compromised structural integrity.

This is to limit the probability of:

  • the excessive deflection or vibration of supported floors, or
  • the excessive movement or deformation of walls.

This is to limit the probability of:

  • compromised operation of doors or windows required for egress in an emergency, and
  • persons losing their balance, tripping or falling.

This is to limit the probability of harm to persons.