Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.3.1.6.(1)
OS2OP2OH1OH4OS3OS1OS2OP2OH1OS3OS2OP2OS3
ObjectiveOS3 Safety in Use
Attribution
(c) [F20,F21,F80-OS3.1]
Application
Application 1: 
Minimum compressive strength of cast-in-place concrete that is not required to be reinforced that is used in garage and carport floors and exterior steps, including steps providing structural support (to guards or handrails, for example), where exposure to de-icing salts, water from rain or melting snow, freezing and thawing stresses, traffic, abrasion or other severe exposure conditions is likely.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Top of Page
Intent
Intent 1: 
To limit the probability of an inadequate resistance to freeze-thaw stresses, de-icing salts, abrasion or traffic, which could lead to the excessive shrinkage, cracking and premature failure of concrete.
This is to limit the probability of:
  • uneven concrete floor or step surfaces, which could lead to persons tripping, or
  • the failure of supported handrails or guards, which could lead to persons falling.
This is to limit the probability of harm to persons.
Top of Page