Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

9.3.1.6.(1)
OS2OP2OH1OH4OS3OS1OS2OP2OH1OS3OS2OP2OS3
ObjectiveOH1 Indoor Conditions
Attribution
(a) [F20,F80-OH1.1] Applies where concrete supports or is used in the walls of chimneys or fireplaces.
(a) [F20,F80,F61,F55-OH1.1,OH1.2] [F20,F80,F61-OH1.3] Applies where concrete supports or is used in an environmental separator.
Application
Application 1: 
Minimum compressive strength of site-batched, cast-in-place concrete that is not required to be reinforced that is used in:
  • footings, foundation walls, walls, columns, grade beams and piers, and
  • fireplaces and chimneys.
This applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9].
Exceptions: 
except as stated in:
  • Sentence 9.12.4.1.(1), which applies to concrete in trenches beneath footing, and
  • the second row of Table 9.15.4.2.A., which applies to concrete in foundation walls, where a structural capacity of 15 MPa is inadequate based on the thickness of the wall and the height of the finish ground above the basement floor or crawl space ground cover.
Top of Page
Intent
Intent 1: 
Where concrete supports or is used in the walls of chimneys or fireplaces, to limit the probability of the inadequate performance or premature failure of concrete under expected environmental or structural loads, which could lead to the failure of these walls.
This is to limit the probability of the leakage of combustion products, which could lead to negative effects on the air quality of indoor spaces.
This is to limit the probability of harm to persons
Intent 2: 
Where concrete supports or is used in an environmental separator, to limit the probability of the inadequate performance or premature failure of concrete under expected environmental or structural loads.
This is to limit the probability of:
  • the compromised integrity of the environmental separator, or
  • an inadequate resistance to air and moisture transfer through the concrete.
This is to limit the probability of:
  • pollutant ingress (from the exterior or from adjacent interior space, including soil gas, combustion products from parking garages, and particulates),
  • precipitation ingress,
  • condensation,
  • the ingress of moisture from the ground, or
  • the compromised thermal performance of components intended to provide resistance to heat transfer.
This is to limit the probability of:
  • the generation of pollutants from biological growth or from materials that become unstable on wetting,
  • deterioration, which could lead to further compromised integrity of environmental separators, or
  • an inadequate control of indoor air and surface temperatures, drafts, relative humidity, or water accumulation.
This is to limit the probability of:
  • negative effects on the air quality of indoor spaces,
  • the inadequate thermal comfort of persons, and
  • contact with moisture.
This is to limit the probability of harm to persons.